The supply voltage must not exceed the operating voltage range; otherwise, it will cause permanent damage to the product!
| Fluid Temperature | 0~90 ℃ (Unfrozen or Uncondensed) | ||
| Display Unit | Instantaneous flow rate L/min, cumulative flow rate L | ||
| Accuracy | Display value: ±3%F.S. Analog output: ±3%F.S. | ||
| Repeatability | ±2%F.S. | ||
| Temperature Characteristics | ±5%F.S. (25°C reference) | ||
| Operating Pressure Range | 0~1MPa | ||
| Withstand Pressure | 1.5MPa | ||
| Pressure Loss (Without Flow Control Valve) | Less than 45kPa at maximum flow rate | ||
| Cumulative Flow Range | 99999999.9L or 999999999L | ||
Switch Output |
- | NPN or PNP open-collector output | |
| Maximum Load Current | 80mA | ||
| Maximum Applied Voltage | DC28V | ||
| Internal Voltage Drop | NPN: Less than 1V (at 80mA load current) PNP: Less than 1.5V (at 80mA load current) | ||
| Response Time | 0.5s/1s/2s | ||
| Output Protection | Short Circuit Protection | ||
| Output Mode |
Flow Rate | Simple mode, hysteresis mode, window comparison mode optional | |
| Temperature | Simple mode, hysteresis mode, window comparison mode optional | ||
Output Mode |
Voltage Output | Output voltage: 1~5V Output impedance: 1kΩ | |
| Current Output | Output current: 4~20mA Maximum load impedance: 600Ω | ||
| RS485 Output | MODBUS RTU | ||
| O-Link Output | COM2 (38.4kBaud) | ||
| Hysteresis | Variable | ||
| Power Supply Voltage | DC12~24V±10% | ||
| Current Consumption | Less than 50mA | ||
Environmental Resistance |
Protective Structure | IP65 | |
| Operating Temperature Range | 0~50℃ (Unfrozen or Uncondensed) | ||
| Operating Humidity Range | During operation, during storage: 35~85%R.H. (Uncondensed) | ||
| Withstand Voltage | AC1000V 1 minute Between charging part and housing | ||
| Insulation Resistance | More than 50MΩ (DC500V megohmmeter) Between charging part and housing | ||
| Certifications and Specifications | CE, UL certifications | ||
| Contact Fluid Material | SUS304, FKM, PBT+30%GF/PPS+40%GF, AL/POM/PVDF/PPS | ||
Application Areas
Flow measurement of industrial pipeline fluids
Keyword:
Related Products
Xinnovis: Trustworthy
Advanced technology, superior quality, and unique service consistently guide industry development.
搜索历史清除全部记录
最多显示8条历史搜索记录噢~
All
- All
- Product Management
- News
- Introduction
- Corporate Outlets
- FAQ
- Corporate Videos
- Corporate Brochures
Tel: 400 006 6550
Office Address: 12. Stock, Gebäude I, Internationaler Innovationspark, Nr. 177 Songling Road, Laoshan District, Qingdao